Blood pool agent strongly improves 3D magnetic resonance coronary angiography using an inversion pre-pulse

Mark B.M. Hofman, Robert E. Henson, Sándor J. Kovács, Stefan E. Fischer, Randall B. Lauffer, Kofi Adzamli, Jan De Becker, Samuel A. Wickline, Christine H. Lorenz

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

The ability of a blood pool contrast agent to enhance MR coronary angiography was defined. The proximal coronary vessels of pigs were imaged before and after administration of Gd-DTPA bound covalently to bovine serum albumin (0.2 mmol/kg). The contrast agent resulted in a reduction of the blood T1 value to 33 ± 5 msec, as determined in vivo with a Look-Locker technique. Both 2D and 3D imaging techniques were performed. An inversion pulse suppressed the signal of nonblood tissue postcontrast. After contrast agent administration, in the 3D data set the signal-to-noise ratio (SNR) of blood and contrast-to-noise ratio (CNR) of blood to myocardium were improved by factors of 2.0 ± 0.2 and 15 ± 8, respectively (P < 0.05). Postcontrast, the 3D acquisition was superior to the 2D technique in terms of spatial resolution, SNR of blood, and CNR of blood to myocardium. The high contrast of the 3D data set allowed for direct and rapid display of coronary arteries using a 'closest vessel projection'.

Original languageEnglish
Pages (from-to)360-367
Number of pages8
JournalMagnetic Resonance in Medicine
Volume41
Issue number2
DOIs
Publication statusPublished - 1 Jan 1999
Externally publishedYes

Cite this

Hofman, Mark B.M. ; Henson, Robert E. ; Kovács, Sándor J. ; Fischer, Stefan E. ; Lauffer, Randall B. ; Adzamli, Kofi ; De Becker, Jan ; Wickline, Samuel A. ; Lorenz, Christine H. / Blood pool agent strongly improves 3D magnetic resonance coronary angiography using an inversion pre-pulse. In: Magnetic Resonance in Medicine. 1999 ; Vol. 41, No. 2. pp. 360-367.
@article{0e44a8535dd34c12861d9cf72c180790,
title = "Blood pool agent strongly improves 3D magnetic resonance coronary angiography using an inversion pre-pulse",
abstract = "The ability of a blood pool contrast agent to enhance MR coronary angiography was defined. The proximal coronary vessels of pigs were imaged before and after administration of Gd-DTPA bound covalently to bovine serum albumin (0.2 mmol/kg). The contrast agent resulted in a reduction of the blood T1 value to 33 ± 5 msec, as determined in vivo with a Look-Locker technique. Both 2D and 3D imaging techniques were performed. An inversion pulse suppressed the signal of nonblood tissue postcontrast. After contrast agent administration, in the 3D data set the signal-to-noise ratio (SNR) of blood and contrast-to-noise ratio (CNR) of blood to myocardium were improved by factors of 2.0 ± 0.2 and 15 ± 8, respectively (P < 0.05). Postcontrast, the 3D acquisition was superior to the 2D technique in terms of spatial resolution, SNR of blood, and CNR of blood to myocardium. The high contrast of the 3D data set allowed for direct and rapid display of coronary arteries using a 'closest vessel projection'.",
keywords = "Blood pool contrast agent, Coronary angiography, Magnetic resonance imaging, Swine",
author = "Hofman, {Mark B.M.} and Henson, {Robert E.} and Kov{\'a}cs, {S{\'a}ndor J.} and Fischer, {Stefan E.} and Lauffer, {Randall B.} and Kofi Adzamli and {De Becker}, Jan and Wickline, {Samuel A.} and Lorenz, {Christine H.}",
year = "1999",
month = "1",
day = "1",
doi = "10.1002/(SICI)1522-2594(199902)41:2<360::AID-MRM21>3.0.CO;2-C",
language = "English",
volume = "41",
pages = "360--367",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "2",

}

Blood pool agent strongly improves 3D magnetic resonance coronary angiography using an inversion pre-pulse. / Hofman, Mark B.M.; Henson, Robert E.; Kovács, Sándor J.; Fischer, Stefan E.; Lauffer, Randall B.; Adzamli, Kofi; De Becker, Jan; Wickline, Samuel A.; Lorenz, Christine H.

In: Magnetic Resonance in Medicine, Vol. 41, No. 2, 01.01.1999, p. 360-367.

Research output: Contribution to journalArticleAcademicpeer-review

TY - JOUR

T1 - Blood pool agent strongly improves 3D magnetic resonance coronary angiography using an inversion pre-pulse

AU - Hofman, Mark B.M.

AU - Henson, Robert E.

AU - Kovács, Sándor J.

AU - Fischer, Stefan E.

AU - Lauffer, Randall B.

AU - Adzamli, Kofi

AU - De Becker, Jan

AU - Wickline, Samuel A.

AU - Lorenz, Christine H.

PY - 1999/1/1

Y1 - 1999/1/1

N2 - The ability of a blood pool contrast agent to enhance MR coronary angiography was defined. The proximal coronary vessels of pigs were imaged before and after administration of Gd-DTPA bound covalently to bovine serum albumin (0.2 mmol/kg). The contrast agent resulted in a reduction of the blood T1 value to 33 ± 5 msec, as determined in vivo with a Look-Locker technique. Both 2D and 3D imaging techniques were performed. An inversion pulse suppressed the signal of nonblood tissue postcontrast. After contrast agent administration, in the 3D data set the signal-to-noise ratio (SNR) of blood and contrast-to-noise ratio (CNR) of blood to myocardium were improved by factors of 2.0 ± 0.2 and 15 ± 8, respectively (P < 0.05). Postcontrast, the 3D acquisition was superior to the 2D technique in terms of spatial resolution, SNR of blood, and CNR of blood to myocardium. The high contrast of the 3D data set allowed for direct and rapid display of coronary arteries using a 'closest vessel projection'.

AB - The ability of a blood pool contrast agent to enhance MR coronary angiography was defined. The proximal coronary vessels of pigs were imaged before and after administration of Gd-DTPA bound covalently to bovine serum albumin (0.2 mmol/kg). The contrast agent resulted in a reduction of the blood T1 value to 33 ± 5 msec, as determined in vivo with a Look-Locker technique. Both 2D and 3D imaging techniques were performed. An inversion pulse suppressed the signal of nonblood tissue postcontrast. After contrast agent administration, in the 3D data set the signal-to-noise ratio (SNR) of blood and contrast-to-noise ratio (CNR) of blood to myocardium were improved by factors of 2.0 ± 0.2 and 15 ± 8, respectively (P < 0.05). Postcontrast, the 3D acquisition was superior to the 2D technique in terms of spatial resolution, SNR of blood, and CNR of blood to myocardium. The high contrast of the 3D data set allowed for direct and rapid display of coronary arteries using a 'closest vessel projection'.

KW - Blood pool contrast agent

KW - Coronary angiography

KW - Magnetic resonance imaging

KW - Swine

UR - http://www.scopus.com/inward/record.url?scp=0033005781&partnerID=8YFLogxK

U2 - 10.1002/(SICI)1522-2594(199902)41:2<360::AID-MRM21>3.0.CO;2-C

DO - 10.1002/(SICI)1522-2594(199902)41:2<360::AID-MRM21>3.0.CO;2-C

M3 - Article

VL - 41

SP - 360

EP - 367

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 2

ER -