Case Report: Pulmonary hemorrhage as a rare cause of lung ultrasound A/B-profile

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

When using lung ultrasound to determine the cause of acute respiratory failure, the BLUE protocol is often used. In a 65-year old patient, an A/B-profile was found, suggesting pneumonia, following the flowchart of this protocol. In this case, however, pulmonary hemorrhage confirmed by bronchoscopy was the final diagnosis. This case report outlines the importance of understanding the limitations of the BLUE protocol and that lung ultrasound findings should always be used in the context of the patient’s history and physical exam. In addition, pulmonary hemorrhage should be considered in patients with no clinical signs of pneumonia and/or presence of risk factors for lung bleeding as a rare cause of lung ultrasound A/B-profile.
Original languageEnglish
Article number788
JournalF1000Research
Volume8
DOIs
Publication statusPublished - 2019

Cite this

@article{0868249f46a742a3824390b7e08c0281,
title = "Case Report: Pulmonary hemorrhage as a rare cause of lung ultrasound A/B-profile",
abstract = "When using lung ultrasound to determine the cause of acute respiratory failure, the BLUE protocol is often used. In a 65-year old patient, an A/B-profile was found, suggesting pneumonia, following the flowchart of this protocol. In this case, however, pulmonary hemorrhage confirmed by bronchoscopy was the final diagnosis. This case report outlines the importance of understanding the limitations of the BLUE protocol and that lung ultrasound findings should always be used in the context of the patient’s history and physical exam. In addition, pulmonary hemorrhage should be considered in patients with no clinical signs of pneumonia and/or presence of risk factors for lung bleeding as a rare cause of lung ultrasound A/B-profile.",
author = "Haaksma, {Mark E.} and Nossent, {Esther J.} and Paul Elbers and Tuinman, {Pieter Roel}",
year = "2019",
doi = "10.12688/f1000research.19329.2",
language = "English",
volume = "8",
journal = "F1000Research",
issn = "2046-1402",
publisher = "F1000 Research Ltd.",

}

TY - JOUR

T1 - Case Report: Pulmonary hemorrhage as a rare cause of lung ultrasound A/B-profile

AU - Haaksma, Mark E.

AU - Nossent, Esther J.

AU - Elbers, Paul

AU - Tuinman, Pieter Roel

PY - 2019

Y1 - 2019

N2 - When using lung ultrasound to determine the cause of acute respiratory failure, the BLUE protocol is often used. In a 65-year old patient, an A/B-profile was found, suggesting pneumonia, following the flowchart of this protocol. In this case, however, pulmonary hemorrhage confirmed by bronchoscopy was the final diagnosis. This case report outlines the importance of understanding the limitations of the BLUE protocol and that lung ultrasound findings should always be used in the context of the patient’s history and physical exam. In addition, pulmonary hemorrhage should be considered in patients with no clinical signs of pneumonia and/or presence of risk factors for lung bleeding as a rare cause of lung ultrasound A/B-profile.

AB - When using lung ultrasound to determine the cause of acute respiratory failure, the BLUE protocol is often used. In a 65-year old patient, an A/B-profile was found, suggesting pneumonia, following the flowchart of this protocol. In this case, however, pulmonary hemorrhage confirmed by bronchoscopy was the final diagnosis. This case report outlines the importance of understanding the limitations of the BLUE protocol and that lung ultrasound findings should always be used in the context of the patient’s history and physical exam. In addition, pulmonary hemorrhage should be considered in patients with no clinical signs of pneumonia and/or presence of risk factors for lung bleeding as a rare cause of lung ultrasound A/B-profile.

UR - https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85072741197&origin=inward

UR - https://www.ncbi.nlm.nih.gov/pubmed/31508213

U2 - 10.12688/f1000research.19329.2

DO - 10.12688/f1000research.19329.2

M3 - Article

VL - 8

JO - F1000Research

JF - F1000Research

SN - 2046-1402

M1 - 788

ER -