T1 - Changes in gastric anatomy after delivery of breath-hold MR-guided SABR for adrenal metastases
AU - van Sörnsen de Koste, John R.
AU - Palacios, Miguel A.
AU - Chen, Hanbo
AU - Schneiders, Famke L.
AU - Bruynzeel, Anna M. E.
AU - Slotman, Berend J.
AU - Haasbeek, Cornelis J. A.
AU - Senan, Suresh
N1 - Funding Information:
The authors would like to acknowledge all clinicians, physicists and technologists in the MRIdian team at the Amsterdam University Medical Center for their contributions to patient care.
Publisher Copyright:
© 2020 The Author(s)
Copyright:
Copyright 2020 Elsevier B.V., All rights reserved.
PY - 2020/11
Y1 - 2020/11
N2 - Delivery of breath-hold MR-guided SABR is time-consuming, and the use of real-time tumor-tracking in a sagittal plane may fail to detect out-of-plane displacements of organs-at-risk. Analysis of daily MR-scans performed pre- and post-SABR revealed frequent decreases in stomach volumes, and in the planned stomach doses.
AB - Delivery of breath-hold MR-guided SABR is time-consuming, and the use of real-time tumor-tracking in a sagittal plane may fail to detect out-of-plane displacements of organs-at-risk. Analysis of daily MR-scans performed pre- and post-SABR revealed frequent decreases in stomach volumes, and in the planned stomach doses.
KW - Adrenal tumors
KW - Gastric anatomy change
KW - Gastric dose change
KW - MR-guided SABR delivery
KW - Organ-at-Risk