T1 - Dosimetric advantages of midventilation compared with internal target volume for radiation therapy of pancreatic cancer
AU - Lens, Eelco
AU - van der Horst, Astrid
AU - Versteijne, Eva
AU - van Tienhoven, Geertjan
AU - Bel, Arjan
PY - 2015
Y1 - 2015
N2 - Purpose The midventilation (midV) approach can be used to take respiratory-induced pancreatic tumor motion into account during radiation therapy. In this study, the dosimetric consequences for organs at risk and tumor coverage of using a midV approach compared with using an internal target volume (ITV) were investigated. Methods and Materials For each of the 18 patients, 2 treatment plans (25 × 2.0 Gy) were created, 1 using an ITV and 1 using a midV approach. The midV dose distribution was blurred using the respiratory-induced motion from 4-dimensional computed tomography. The resulting planning target volume (PTV) coverage for this blurred dose distribution was analyzed; PTV coverage was required to be at least V95% >98%. In addition, the change in PTV size and the changes in V10Gy, V20Gy, V30Gy, V40Gy, Dmean and D2cc for the stomach and for the duodenum were analyzed; differences were tested for significance using the Wilcoxon signed-rank test. Results Using a midV approach resulted in sufficient target coverage. A highly significant PTV size reduction of 13.9% (P<.001) was observed. Also, all dose parameters for the stomach and duodenum, except the D2cc of the duodenum, improved significantly (P≤.002). Conclusions By using the midV approach to account for respiratory-induced tumor motion, a significant PTV reduction and significant dose reductions to the stomach and to the duodenum can be achieved when irradiating pancreatic tumors.
AB - Purpose The midventilation (midV) approach can be used to take respiratory-induced pancreatic tumor motion into account during radiation therapy. In this study, the dosimetric consequences for organs at risk and tumor coverage of using a midV approach compared with using an internal target volume (ITV) were investigated. Methods and Materials For each of the 18 patients, 2 treatment plans (25 × 2.0 Gy) were created, 1 using an ITV and 1 using a midV approach. The midV dose distribution was blurred using the respiratory-induced motion from 4-dimensional computed tomography. The resulting planning target volume (PTV) coverage for this blurred dose distribution was analyzed; PTV coverage was required to be at least V95% >98%. In addition, the change in PTV size and the changes in V10Gy, V20Gy, V30Gy, V40Gy, Dmean and D2cc for the stomach and for the duodenum were analyzed; differences were tested for significance using the Wilcoxon signed-rank test. Results Using a midV approach resulted in sufficient target coverage. A highly significant PTV size reduction of 13.9% (P<.001) was observed. Also, all dose parameters for the stomach and duodenum, except the D2cc of the duodenum, improved significantly (P≤.002). Conclusions By using the midV approach to account for respiratory-induced tumor motion, a significant PTV reduction and significant dose reductions to the stomach and to the duodenum can be achieved when irradiating pancreatic tumors.
UR - https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84930575350&origin=inward
UR - https://www.ncbi.nlm.nih.gov/pubmed/25892585
U2 - 10.1016/j.ijrobp.2015.02.015
DO - 10.1016/j.ijrobp.2015.02.015
M3 - Article
C2 - 25892585
VL - 92
SP - 675
EP - 682
JO - International Journal of Radiation Oncology Biology Physics
JF - International Journal of Radiation Oncology Biology Physics
SN - 0360-3016
IS - 3
ER -