Laboratory Tests: Blood Gases, Anion Gap, and Strong Ion Gap.

Research output: Chapter in Book/Report/Conference proceedingChapterAcademicpeer-review

Abstract

Blood gas measurements provide the intensivist with diagnostic information on many organ systems. The anion gap (AG) and the strong ion gap (SIG) exploit the principle of electroneutrality to quantify the net balance of unmeasured ions in plasma. The AG should be corrected for abnormalities in plasma albumin and phosphate concentrations. The AG and SIG can be used to narrow the differential diagnosis of acid-base disorders, and an increased corrected AG or SIG is diagnostic of a metabolic acidosis (i.e., an acidifying process) irrespective of plasma pH or bicarbonate. The SIG is often perceived as more complex but frequently yields more precise results in critically ill patients. In addition, the strong ion model can be used to guide fluid management because it acknowledges that electrolyte changes are causal mechanisms of acid-base disorders.

Original languageEnglish
Title of host publicationCritical Care Nephrology
Subtitle of host publicationThird Edition
PublisherElsevier Inc.
Pages374-378
Number of pages5
ISBN (Electronic)9780323449427
ISBN (Print)9780323449427
DOIs
Publication statusPublished - 6 Dec 2017

Cite this

de Grooth, H. J., Schraverus, P., & Elbers, P. W. G. (2017). Laboratory Tests: Blood Gases, Anion Gap, and Strong Ion Gap. In Critical Care Nephrology: Third Edition (pp. 374-378). Elsevier Inc.. https://doi.org/10.1016/B978-0-323-44942-7.00064-9
de Grooth, Harm Jan ; Schraverus, Pieter ; Elbers, Paul W.G. / Laboratory Tests : Blood Gases, Anion Gap, and Strong Ion Gap. Critical Care Nephrology: Third Edition. Elsevier Inc., 2017. pp. 374-378
@inbook{5e153af72b394579945634f91f454dac,
title = "Laboratory Tests: Blood Gases, Anion Gap, and Strong Ion Gap.",
abstract = "Blood gas measurements provide the intensivist with diagnostic information on many organ systems. The anion gap (AG) and the strong ion gap (SIG) exploit the principle of electroneutrality to quantify the net balance of unmeasured ions in plasma. The AG should be corrected for abnormalities in plasma albumin and phosphate concentrations. The AG and SIG can be used to narrow the differential diagnosis of acid-base disorders, and an increased corrected AG or SIG is diagnostic of a metabolic acidosis (i.e., an acidifying process) irrespective of plasma pH or bicarbonate. The SIG is often perceived as more complex but frequently yields more precise results in critically ill patients. In addition, the strong ion model can be used to guide fluid management because it acknowledges that electrolyte changes are causal mechanisms of acid-base disorders.",
keywords = "Acid-base disorders, Anion gap, Electrolytes, Strong ion difference, Strong ion gap",
author = "{de Grooth}, {Harm Jan} and Pieter Schraverus and Elbers, {Paul W.G.}",
year = "2017",
month = "12",
day = "6",
doi = "10.1016/B978-0-323-44942-7.00064-9",
language = "English",
isbn = "9780323449427",
pages = "374--378",
booktitle = "Critical Care Nephrology",
publisher = "Elsevier Inc.",
address = "United States",

}

de Grooth, HJ, Schraverus, P & Elbers, PWG 2017, Laboratory Tests: Blood Gases, Anion Gap, and Strong Ion Gap. in Critical Care Nephrology: Third Edition. Elsevier Inc., pp. 374-378. https://doi.org/10.1016/B978-0-323-44942-7.00064-9

Laboratory Tests : Blood Gases, Anion Gap, and Strong Ion Gap. / de Grooth, Harm Jan; Schraverus, Pieter; Elbers, Paul W.G.

Critical Care Nephrology: Third Edition. Elsevier Inc., 2017. p. 374-378.

Research output: Chapter in Book/Report/Conference proceedingChapterAcademicpeer-review

TY - CHAP

T1 - Laboratory Tests

T2 - Blood Gases, Anion Gap, and Strong Ion Gap.

AU - de Grooth, Harm Jan

AU - Schraverus, Pieter

AU - Elbers, Paul W.G.

PY - 2017/12/6

Y1 - 2017/12/6

N2 - Blood gas measurements provide the intensivist with diagnostic information on many organ systems. The anion gap (AG) and the strong ion gap (SIG) exploit the principle of electroneutrality to quantify the net balance of unmeasured ions in plasma. The AG should be corrected for abnormalities in plasma albumin and phosphate concentrations. The AG and SIG can be used to narrow the differential diagnosis of acid-base disorders, and an increased corrected AG or SIG is diagnostic of a metabolic acidosis (i.e., an acidifying process) irrespective of plasma pH or bicarbonate. The SIG is often perceived as more complex but frequently yields more precise results in critically ill patients. In addition, the strong ion model can be used to guide fluid management because it acknowledges that electrolyte changes are causal mechanisms of acid-base disorders.

AB - Blood gas measurements provide the intensivist with diagnostic information on many organ systems. The anion gap (AG) and the strong ion gap (SIG) exploit the principle of electroneutrality to quantify the net balance of unmeasured ions in plasma. The AG should be corrected for abnormalities in plasma albumin and phosphate concentrations. The AG and SIG can be used to narrow the differential diagnosis of acid-base disorders, and an increased corrected AG or SIG is diagnostic of a metabolic acidosis (i.e., an acidifying process) irrespective of plasma pH or bicarbonate. The SIG is often perceived as more complex but frequently yields more precise results in critically ill patients. In addition, the strong ion model can be used to guide fluid management because it acknowledges that electrolyte changes are causal mechanisms of acid-base disorders.

KW - Acid-base disorders

KW - Anion gap

KW - Electrolytes

KW - Strong ion difference

KW - Strong ion gap

UR - http://www.scopus.com/inward/record.url?scp=85055372136&partnerID=8YFLogxK

U2 - 10.1016/B978-0-323-44942-7.00064-9

DO - 10.1016/B978-0-323-44942-7.00064-9

M3 - Chapter

SN - 9780323449427

SP - 374

EP - 378

BT - Critical Care Nephrology

PB - Elsevier Inc.

ER -

de Grooth HJ, Schraverus P, Elbers PWG. Laboratory Tests: Blood Gases, Anion Gap, and Strong Ion Gap. In Critical Care Nephrology: Third Edition. Elsevier Inc. 2017. p. 374-378 https://doi.org/10.1016/B978-0-323-44942-7.00064-9