Maximum-likelihood reconstruction based on a modified Poisson distribution to reduce bias in PET

Johan Nuyts, Simon Stute, Katrien Van Slambrouck, Floris Van Velden, Ronald Boellaard, Claude Comtat

Research output: Chapter in Book/Report/Conference proceedingConference contributionAcademicpeer-review

Original languageEnglish
Title of host publication2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011
Pages4337-4341
Number of pages5
DOIs
Publication statusPublished - 26 Mar 2012
Event2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011 - Valencia, Spain
Duration: 23 Oct 201129 Oct 2011

Conference

Conference2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011
CountrySpain
CityValencia
Period23/10/201129/10/2011

Cite this

Nuyts, J., Stute, S., Van Slambrouck, K., Van Velden, F., Boellaard, R., & Comtat, C. (2012). Maximum-likelihood reconstruction based on a modified Poisson distribution to reduce bias in PET. In 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011 (pp. 4337-4341). [6153835] https://doi.org/10.1109/NSSMIC.2011.6153835
Nuyts, Johan ; Stute, Simon ; Van Slambrouck, Katrien ; Van Velden, Floris ; Boellaard, Ronald ; Comtat, Claude. / Maximum-likelihood reconstruction based on a modified Poisson distribution to reduce bias in PET. 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011. 2012. pp. 4337-4341
@inproceedings{afa24d7a61fb4518a90ce587cdba5fc8,
title = "Maximum-likelihood reconstruction based on a modified Poisson distribution to reduce bias in PET",
author = "Johan Nuyts and Simon Stute and {Van Slambrouck}, Katrien and {Van Velden}, Floris and Ronald Boellaard and Claude Comtat",
year = "2012",
month = "3",
day = "26",
doi = "10.1109/NSSMIC.2011.6153835",
language = "English",
isbn = "9781467301183",
pages = "4337--4341",
booktitle = "2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011",

}

Nuyts, J, Stute, S, Van Slambrouck, K, Van Velden, F, Boellaard, R & Comtat, C 2012, Maximum-likelihood reconstruction based on a modified Poisson distribution to reduce bias in PET. in 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011., 6153835, pp. 4337-4341, 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011, Valencia, Spain, 23/10/2011. https://doi.org/10.1109/NSSMIC.2011.6153835

Maximum-likelihood reconstruction based on a modified Poisson distribution to reduce bias in PET. / Nuyts, Johan; Stute, Simon; Van Slambrouck, Katrien; Van Velden, Floris; Boellaard, Ronald; Comtat, Claude.

2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011. 2012. p. 4337-4341 6153835.

Research output: Chapter in Book/Report/Conference proceedingConference contributionAcademicpeer-review

TY - GEN

T1 - Maximum-likelihood reconstruction based on a modified Poisson distribution to reduce bias in PET

AU - Nuyts, Johan

AU - Stute, Simon

AU - Van Slambrouck, Katrien

AU - Van Velden, Floris

AU - Boellaard, Ronald

AU - Comtat, Claude

PY - 2012/3/26

Y1 - 2012/3/26

UR - http://www.scopus.com/inward/record.url?scp=84858673412&partnerID=8YFLogxK

U2 - 10.1109/NSSMIC.2011.6153835

DO - 10.1109/NSSMIC.2011.6153835

M3 - Conference contribution

SN - 9781467301183

SP - 4337

EP - 4341

BT - 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011

ER -

Nuyts J, Stute S, Van Slambrouck K, Van Velden F, Boellaard R, Comtat C. Maximum-likelihood reconstruction based on a modified Poisson distribution to reduce bias in PET. In 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011. 2012. p. 4337-4341. 6153835 https://doi.org/10.1109/NSSMIC.2011.6153835