TY - JOUR
T1 - Stent placement for renal arterial stenosis
T2 - Where do we stand? A meta- analysis
AU - Leertouwer, Trude C.
AU - Gussenhoven, Elma J.
AU - Bosch, Johanna L.
AU - Van Jaarsveld, Brigit C.
AU - Van Dijk, Lukas C.
AU - Deinum, Jaap
AU - Manin't Veld, Arie J.
PY - 2000/1/1
Y1 - 2000/1/1
N2 - PURPOSE: To perform a meta-analysis of renal arterial stent placement in comparison with renal percutaneous transluminal angioplasty (PTA) in patients with renal arterial stenosis. MATERIALS AND METHODS: Studies dealing with renal arterial stent placement (14 articles; 678 patients) and renal PTA (10 articles; 644 patients) published up to August 1998 were selected. A random- effects model was used to pool the data. RESULTS: Renal arterial stent placement proved highly successful, with an initial adequate performance in 98% and major complications in 11%. The overall cure rate for hypertension was 20%, whereas hypertension was improved in 49%. Renal function improved in 30% and stabilized in 38% of patients. The restenosis rate at follow-up of 6- 29 months was 17%. Stent placement had a higher technical success rate and a lower restenosis rate than did renal PTA (98% vs 77% and 17% vs 26%, respectively; P < .001). The complication rate was not different between the two treatments. The cure rate for hypertension was higher and the improvement rate for renal function was lower after stent placement than after renal PTA (20% vs 10% and 30% vs 38%, respectively; P < .001). CONCLUSION: Renal arterial stent placement is technically superior and clinically comparable to renal PTA alone.
AB - PURPOSE: To perform a meta-analysis of renal arterial stent placement in comparison with renal percutaneous transluminal angioplasty (PTA) in patients with renal arterial stenosis. MATERIALS AND METHODS: Studies dealing with renal arterial stent placement (14 articles; 678 patients) and renal PTA (10 articles; 644 patients) published up to August 1998 were selected. A random- effects model was used to pool the data. RESULTS: Renal arterial stent placement proved highly successful, with an initial adequate performance in 98% and major complications in 11%. The overall cure rate for hypertension was 20%, whereas hypertension was improved in 49%. Renal function improved in 30% and stabilized in 38% of patients. The restenosis rate at follow-up of 6- 29 months was 17%. Stent placement had a higher technical success rate and a lower restenosis rate than did renal PTA (98% vs 77% and 17% vs 26%, respectively; P < .001). The complication rate was not different between the two treatments. The cure rate for hypertension was higher and the improvement rate for renal function was lower after stent placement than after renal PTA (20% vs 10% and 30% vs 38%, respectively; P < .001). CONCLUSION: Renal arterial stent placement is technically superior and clinically comparable to renal PTA alone.
KW - Arteries, grafts and prostheses
KW - Hypertension, renovascular
KW - Renal arteries, stenosis or obstruction
KW - Renal arteries, transluminal angioplasty,
KW - Stents and prostheses
UR - http://www.scopus.com/inward/record.url?scp=0033932513&partnerID=8YFLogxK
U2 - 10.1148/radiology.216.1.r00jl0778
DO - 10.1148/radiology.216.1.r00jl0778
M3 - Article
C2 - 10887230
AN - SCOPUS:0033932513
VL - 216
SP - 78
EP - 85
JO - Radiology Now
JF - Radiology Now
SN - 0033-8419
IS - 1
ER -