N2 - BACKGROUND: A variety of diagnostic imaging techniques is available for excluding or confirming chronic osteomyelitis. Until now, an evidence-based algorithmic model for choosing the most suitable imaging technique has been lacking. The objective of this study was to determine the accuracy of current imaging modalities in the diagnosis of chronic osteomyelitis.METHODS: A systematic review and meta-analysis of the literature was conducted with a comprehensive search of the MEDLINE, EMBASE, and Current Contents databases to identify clinical studies on chronic osteomyelitis that evaluated diagnostic imaging modalities. The value of each imaging technique was studied by determining its sensitivity and specificity compared with the results of histological analysis, findings on culture, and clinical follow-up of more than six months.RESULTS: A total of twenty-three clinical studies in which the accuracy was described for radiography (two studies), magnetic resonance imaging (five), computed tomography (one), bone scintigraphy (seven), leukocyte scintigraphy (thirteen), gallium scintigraphy (one), combined bone and leukocyte scintigraphy (six), combined bone and gallium scintigraphy (three), and fluorodeoxyglucose positron emission tomography (four) were included in the review. No meta-analysis was performed with respect to computed tomography, gallium scintigraphy, and radiography. Pooled sensitivity demonstrated that fluorodeoxyglucose positron emission tomography was the most sensitive technique, with a sensitivity of 96% (95% confidence interval, 88% to 99%) compared with 82% (95% confidence interval, 70% to 89%) for bone scintigraphy, 61% (95% confidence interval, 43% to 76%) for leukocyte scintigraphy, 78% (95% confidence interval, 72% to 83%) for combined bone and leukocyte scintigraphy, and 84% (95% confidence interval, 69% to 92%) for magnetic resonance imaging. Pooled specificity demonstrated that bone scintigraphy had the lowest specificity, with a specificity of 25% (95% confidence interval, 16% to 36%) compared with 60% (95% confidence interval, 38% to 78%) for magnetic resonance imaging, 77% (95% confidence interval, 63% to 87%) for leukocyte scintigraphy, 84% (95% confidence interval, 75% to 90%) for combined bone and leukocyte scintigraphy, and 91% (95% confidence interval, 81% to 95%) for fluorodeoxyglucose positron emission tomography. The sensitivity of leukocyte scintigraphy in detecting chronic osteomyelitis in the peripheral skeleton was 84% (95% confidence interval, 72% to 91%) compared with 21% (95% confidence interval, 11% to 38%) for its detection of chronic osteomyelitis in the axial skeleton. The specificity of leukocyte scintigraphy in the axial skeleton was 60% (95% confidence interval, 39% to 78%) compared with 80% (95% confidence interval, 61% to 91%) for the peripheral skeleton.CONCLUSIONS: Fluorodeoxyglucose positron emission tomography has the highest diagnostic accuracy for confirming or excluding the diagnosis of chronic osteomyelitis. Leukocyte scintigraphy has an appropriate diagnostic accuracy in the peripheral skeleton, but fluorodeoxyglucose positron emission tomography is superior for detecting chronic osteomyelitis in the axial skeleton.
AB - BACKGROUND: A variety of diagnostic imaging techniques is available for excluding or confirming chronic osteomyelitis. Until now, an evidence-based algorithmic model for choosing the most suitable imaging technique has been lacking. The objective of this study was to determine the accuracy of current imaging modalities in the diagnosis of chronic osteomyelitis.METHODS: A systematic review and meta-analysis of the literature was conducted with a comprehensive search of the MEDLINE, EMBASE, and Current Contents databases to identify clinical studies on chronic osteomyelitis that evaluated diagnostic imaging modalities. The value of each imaging technique was studied by determining its sensitivity and specificity compared with the results of histological analysis, findings on culture, and clinical follow-up of more than six months.RESULTS: A total of twenty-three clinical studies in which the accuracy was described for radiography (two studies), magnetic resonance imaging (five), computed tomography (one), bone scintigraphy (seven), leukocyte scintigraphy (thirteen), gallium scintigraphy (one), combined bone and leukocyte scintigraphy (six), combined bone and gallium scintigraphy (three), and fluorodeoxyglucose positron emission tomography (four) were included in the review. No meta-analysis was performed with respect to computed tomography, gallium scintigraphy, and radiography. Pooled sensitivity demonstrated that fluorodeoxyglucose positron emission tomography was the most sensitive technique, with a sensitivity of 96% (95% confidence interval, 88% to 99%) compared with 82% (95% confidence interval, 70% to 89%) for bone scintigraphy, 61% (95% confidence interval, 43% to 76%) for leukocyte scintigraphy, 78% (95% confidence interval, 72% to 83%) for combined bone and leukocyte scintigraphy, and 84% (95% confidence interval, 69% to 92%) for magnetic resonance imaging. Pooled specificity demonstrated that bone scintigraphy had the lowest specificity, with a specificity of 25% (95% confidence interval, 16% to 36%) compared with 60% (95% confidence interval, 38% to 78%) for magnetic resonance imaging, 77% (95% confidence interval, 63% to 87%) for leukocyte scintigraphy, 84% (95% confidence interval, 75% to 90%) for combined bone and leukocyte scintigraphy, and 91% (95% confidence interval, 81% to 95%) for fluorodeoxyglucose positron emission tomography. The sensitivity of leukocyte scintigraphy in detecting chronic osteomyelitis in the peripheral skeleton was 84% (95% confidence interval, 72% to 91%) compared with 21% (95% confidence interval, 11% to 38%) for its detection of chronic osteomyelitis in the axial skeleton. The specificity of leukocyte scintigraphy in the axial skeleton was 60% (95% confidence interval, 39% to 78%) compared with 80% (95% confidence interval, 61% to 91%) for the peripheral skeleton.CONCLUSIONS: Fluorodeoxyglucose positron emission tomography has the highest diagnostic accuracy for confirming or excluding the diagnosis of chronic osteomyelitis. Leukocyte scintigraphy has an appropriate diagnostic accuracy in the peripheral skeleton, but fluorodeoxyglucose positron emission tomography is superior for detecting chronic osteomyelitis in the axial skeleton.
KW - Chronic Disease
KW - Fluorodeoxyglucose F18
KW - Humans
KW - Osteomyelitis/diagnosis
KW - Positron-Emission Tomography/methods
KW - Radionuclide Imaging/methods
KW - Radiopharmaceuticals
KW - Reproducibility of Results
KW - Sensitivity and Specificity
KW - MR imaging
KW - chronic ostemyelitis
KW - white blood cells
KW - Systematic literature review
KW - Diagnostic accuracy
KW - FDG PET
KW - Computed tomography (CT)
KW - Technetium
KW - bone metabolism
KW - Magnetic Resonance Imaging
KW - gallium scintigraphy
KW - Bone seeking radiopharmaceutical
U2 - 10.2106/JBJS.D.02691
DO - 10.2106/JBJS.D.02691
M3 - Review article
C2 - 16264122
SN - 0021-9355
VL - 87
SP - 2464
EP - 2471
JO - Journal of Bone and Joint Surgery. American Volume
JF - Journal of Bone and Joint Surgery. American Volume
IS - 11