TY - JOUR
T1 - The reliability of measuring medial gastrocnemius muscle-tendon unit lengths during gait
AU - Cenni, Francesco
AU - Schless, Simon-Henri
AU - Adams, Heleen
AU - Bar-On, Lynn
AU - Desloovere, Kaat
N1 - Funding Information:
We would like to acknowledge the Promobilia Foundation, the Research Foundation Flanders and the Netherlands Organization for Scientific Research for funding. The sponsors had no role in the design and conduct of this study; collection analysis, and interpretation of data; preparation, review or approval of the manuscript; and decision to submit the manuscript for publication.
Publisher Copyright:
© 2021 Elsevier B.V.
Copyright:
Copyright 2021 Elsevier B.V., All rights reserved.
PY - 2021/10/1
Y1 - 2021/10/1
N2 - Background: Ultrasound imaging combined with 3D motion analysis allows for in-vivo assessment of muscle-tendon unit lengths during gait. The clinical relevance of analysing the medial gastrocnemius (MG) and Achilles muscle-tendon junction (MTJ), MG mid-muscle belly fascicles (FAS) and muscle thickness was shown. However, their reliability error estimations over the gait cycle is unknown. Research question: What are the intra- and inter-session errors associated with extracting MG belly, thickness, FAS and tendon lengths using ultrasound during gait in healthy participants? Methods: 3D gait analysis was carried out in ten healthy adults as they walked on an instrumented treadmill at a comfortable walking speed. An ultrasound probe was secured on the leg and tracked by 3D motion analysis. Images were collected during two walking trials with the probe on the MG muscle-belly to estimate FAS lengths and muscle thickness, and during two trials with the probe on the MTJ to estimate muscle-belly and tendon lengths. A second session was performed after 5 ± 4 days where a different operator placed the ultrasound probe. The standard deviation (SD) of absolute and relative lengths changes during the gait cycle over different trials were calculated per participant. SD values averaged over participants represented intra- and inter-session errors. Results: For all assessed variables, the intra-session errors were <2.2 mm, except for the FAS lengths (3.1 mm). The inter-session errors were larger than the intra-session, with the highest values found for the absolute muscle-tendon unit lengths (5.6 mm). Relative length errors were smaller than absolute length errors. Significance: Intra-session errors, which may reflect natural variability and data processing errors, seem more critical when extracting absolute FAS than muscle-tendon lengths. Standardized probe positioning on the MTJ between sessions may improve the inter-session reliability. Expressing the lengths relative to their lengths as the beginning of the gait cycle reduces the inter-session errors.
AB - Background: Ultrasound imaging combined with 3D motion analysis allows for in-vivo assessment of muscle-tendon unit lengths during gait. The clinical relevance of analysing the medial gastrocnemius (MG) and Achilles muscle-tendon junction (MTJ), MG mid-muscle belly fascicles (FAS) and muscle thickness was shown. However, their reliability error estimations over the gait cycle is unknown. Research question: What are the intra- and inter-session errors associated with extracting MG belly, thickness, FAS and tendon lengths using ultrasound during gait in healthy participants? Methods: 3D gait analysis was carried out in ten healthy adults as they walked on an instrumented treadmill at a comfortable walking speed. An ultrasound probe was secured on the leg and tracked by 3D motion analysis. Images were collected during two walking trials with the probe on the MG muscle-belly to estimate FAS lengths and muscle thickness, and during two trials with the probe on the MTJ to estimate muscle-belly and tendon lengths. A second session was performed after 5 ± 4 days where a different operator placed the ultrasound probe. The standard deviation (SD) of absolute and relative lengths changes during the gait cycle over different trials were calculated per participant. SD values averaged over participants represented intra- and inter-session errors. Results: For all assessed variables, the intra-session errors were <2.2 mm, except for the FAS lengths (3.1 mm). The inter-session errors were larger than the intra-session, with the highest values found for the absolute muscle-tendon unit lengths (5.6 mm). Relative length errors were smaller than absolute length errors. Significance: Intra-session errors, which may reflect natural variability and data processing errors, seem more critical when extracting absolute FAS than muscle-tendon lengths. Standardized probe positioning on the MTJ between sessions may improve the inter-session reliability. Expressing the lengths relative to their lengths as the beginning of the gait cycle reduces the inter-session errors.
KW - Dynamic ultrasound
KW - Gait analysis
KW - Lower limb muscle-tendon
KW - Reliability
UR - http://www.scopus.com/inward/record.url?scp=85116366262&partnerID=8YFLogxK
U2 - 10.1016/j.gaitpost.2021.09.198
DO - 10.1016/j.gaitpost.2021.09.198
M3 - Article
C2 - 34619612
SN - 0966-6362
VL - 90
SP - 464
EP - 467
JO - Gait and Posture
JF - Gait and Posture
ER -