The Use of Plain Radiography, Subtraction Arthrography, Nuclear Arthrography, and Bone Scintigraphy in the Diagnosis of a Loose Acetabular Component of a Total Hip Prosthesis. A Systematic Review

Olivier P.P. Temmerman, Pieter G.H.M. Raijmakers, Walter L. Deville, Johannes Berkhof, Lotty Hooft, Ide C. Heyligers

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

This meta-analysis was performed to summarize and compare the diagnostic performance and diagnostic accuracy of radiographic and scintigraphic techniques in the evaluation of patients suspected of having aseptically loose acetabular components. Twenty-eight studies, published between January 1975 and October 2004, presented sufficient data for quantitative analysis. The pooled sensitivity and specificity rates for plain radiography were 70% (95% confidence interval [CI] = 59%-79%) and 80% (95% CI = 73%-86%), respectively; those for subtraction arthrography were 89% (95% CI = 84%-93%) and 76% (95% CI = 68%-82%), respectively; and those for nuclear arthrography were 87% (95% CI = 57%-97%) and 64% (95% CI = 40%-82%), respectively. Finally, bone scintigraphy had a sensitivity of 67% (95% CI = 57%-76%) and a specificity of 75% (95% CI = 64%-83%). We found a significantly higher sensitivity for subtraction arthrography as compared with plain radiography and bone scintigraphy. Therefore, subtraction arthrography is recommended for use as an additional diagnostic technique when plain radiography is found to be inconclusive.

Original languageEnglish
Pages (from-to)818-827
Number of pages10
JournalJournal of Arthroplasty
Volume22
Issue number6
DOIs
Publication statusPublished - 1 Sep 2007

Cite this

@article{3ef94c94daae4c58bb3f0be9183ee5b1,
title = "The Use of Plain Radiography, Subtraction Arthrography, Nuclear Arthrography, and Bone Scintigraphy in the Diagnosis of a Loose Acetabular Component of a Total Hip Prosthesis. A Systematic Review",
abstract = "This meta-analysis was performed to summarize and compare the diagnostic performance and diagnostic accuracy of radiographic and scintigraphic techniques in the evaluation of patients suspected of having aseptically loose acetabular components. Twenty-eight studies, published between January 1975 and October 2004, presented sufficient data for quantitative analysis. The pooled sensitivity and specificity rates for plain radiography were 70{\%} (95{\%} confidence interval [CI] = 59{\%}-79{\%}) and 80{\%} (95{\%} CI = 73{\%}-86{\%}), respectively; those for subtraction arthrography were 89{\%} (95{\%} CI = 84{\%}-93{\%}) and 76{\%} (95{\%} CI = 68{\%}-82{\%}), respectively; and those for nuclear arthrography were 87{\%} (95{\%} CI = 57{\%}-97{\%}) and 64{\%} (95{\%} CI = 40{\%}-82{\%}), respectively. Finally, bone scintigraphy had a sensitivity of 67{\%} (95{\%} CI = 57{\%}-76{\%}) and a specificity of 75{\%} (95{\%} CI = 64{\%}-83{\%}). We found a significantly higher sensitivity for subtraction arthrography as compared with plain radiography and bone scintigraphy. Therefore, subtraction arthrography is recommended for use as an additional diagnostic technique when plain radiography is found to be inconclusive.",
keywords = "acetabulum, arthrography, radiography, radionuclide imaging, systematic review",
author = "Temmerman, {Olivier P.P.} and Raijmakers, {Pieter G.H.M.} and Deville, {Walter L.} and Johannes Berkhof and Lotty Hooft and Heyligers, {Ide C.}",
year = "2007",
month = "9",
day = "1",
doi = "10.1016/j.arth.2006.08.004",
language = "English",
volume = "22",
pages = "818--827",
journal = "The Journal of Arthroplasty",
issn = "0883-5403",
publisher = "Churchill Livingstone",
number = "6",

}

The Use of Plain Radiography, Subtraction Arthrography, Nuclear Arthrography, and Bone Scintigraphy in the Diagnosis of a Loose Acetabular Component of a Total Hip Prosthesis. A Systematic Review. / Temmerman, Olivier P.P.; Raijmakers, Pieter G.H.M.; Deville, Walter L.; Berkhof, Johannes; Hooft, Lotty; Heyligers, Ide C.

In: Journal of Arthroplasty, Vol. 22, No. 6, 01.09.2007, p. 818-827.

Research output: Contribution to journalArticleAcademicpeer-review

TY - JOUR

T1 - The Use of Plain Radiography, Subtraction Arthrography, Nuclear Arthrography, and Bone Scintigraphy in the Diagnosis of a Loose Acetabular Component of a Total Hip Prosthesis. A Systematic Review

AU - Temmerman, Olivier P.P.

AU - Raijmakers, Pieter G.H.M.

AU - Deville, Walter L.

AU - Berkhof, Johannes

AU - Hooft, Lotty

AU - Heyligers, Ide C.

PY - 2007/9/1

Y1 - 2007/9/1

N2 - This meta-analysis was performed to summarize and compare the diagnostic performance and diagnostic accuracy of radiographic and scintigraphic techniques in the evaluation of patients suspected of having aseptically loose acetabular components. Twenty-eight studies, published between January 1975 and October 2004, presented sufficient data for quantitative analysis. The pooled sensitivity and specificity rates for plain radiography were 70% (95% confidence interval [CI] = 59%-79%) and 80% (95% CI = 73%-86%), respectively; those for subtraction arthrography were 89% (95% CI = 84%-93%) and 76% (95% CI = 68%-82%), respectively; and those for nuclear arthrography were 87% (95% CI = 57%-97%) and 64% (95% CI = 40%-82%), respectively. Finally, bone scintigraphy had a sensitivity of 67% (95% CI = 57%-76%) and a specificity of 75% (95% CI = 64%-83%). We found a significantly higher sensitivity for subtraction arthrography as compared with plain radiography and bone scintigraphy. Therefore, subtraction arthrography is recommended for use as an additional diagnostic technique when plain radiography is found to be inconclusive.

AB - This meta-analysis was performed to summarize and compare the diagnostic performance and diagnostic accuracy of radiographic and scintigraphic techniques in the evaluation of patients suspected of having aseptically loose acetabular components. Twenty-eight studies, published between January 1975 and October 2004, presented sufficient data for quantitative analysis. The pooled sensitivity and specificity rates for plain radiography were 70% (95% confidence interval [CI] = 59%-79%) and 80% (95% CI = 73%-86%), respectively; those for subtraction arthrography were 89% (95% CI = 84%-93%) and 76% (95% CI = 68%-82%), respectively; and those for nuclear arthrography were 87% (95% CI = 57%-97%) and 64% (95% CI = 40%-82%), respectively. Finally, bone scintigraphy had a sensitivity of 67% (95% CI = 57%-76%) and a specificity of 75% (95% CI = 64%-83%). We found a significantly higher sensitivity for subtraction arthrography as compared with plain radiography and bone scintigraphy. Therefore, subtraction arthrography is recommended for use as an additional diagnostic technique when plain radiography is found to be inconclusive.

KW - acetabulum

KW - arthrography

KW - radiography

KW - radionuclide imaging

KW - systematic review

UR - http://www.scopus.com/inward/record.url?scp=34548420953&partnerID=8YFLogxK

U2 - 10.1016/j.arth.2006.08.004

DO - 10.1016/j.arth.2006.08.004

M3 - Article

VL - 22

SP - 818

EP - 827

JO - The Journal of Arthroplasty

JF - The Journal of Arthroplasty

SN - 0883-5403

IS - 6

ER -