Thickness measurement of worn molar cusps by ultrasound

D. Arslantunali Tagtekin, F. Öztürk, M. Lagerweij, O. Hayran, G. K. Stookey, F. Çaliskan Yanikoglu*

*Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

This study aimed to evaluate the effectiveness of an ultrasonic system for in vitro measurement of cusp tips of human teeth. Each worn cusp of 12 molar teeth was measured with an industrial ultrasonic system. The teeth were sectioned and measured by polarized light microscopy. The ultrasonic measurements and histological readings were moderately correlated (r = 0.601, p < 0.01). The ultrasonic system used in this study seemed a promising method for measuring thickness of worn cusp tips of extracted human molar teeth.